Challenge
How to account for the increased loading on the roof of the adjacent heritage building from snow that can result from the addition of the new 75 James tower as dictated by the local building code.
Solution
Entuitive commissioned a snow study conducted in a wind tunnel that accounted for the actual expected snow accumulations taking into account the prevailing winds in the area that are available to prevent snow buildup on the roof of the heritage building avoiding costly reinforcing of the 100 year old structure.